Temperature Controlled Reactors


Sample-to-sample thermal uniformity can be difficult to achieve with high-throughput chemistry. Extreme temperature differences, thermal inconsistency, and thermal overload can all impact experimental validity, especially when using techniques like photocatalysis. The TCR solves these issues.
Standard 96 or 24-well reactor blocks have no internal fluid path and no way to accurately set and control temperature uniformity. As such, high-powered LEDs used for photocatalysis reactions can produce an overall reactor heat gradient of up to +/- 13°C, with severe heat island effects. Analytical’s TCRs are capable of controlling temperatures to a uniformity of +/- 1°C. Compatibility is one of the most important parameters of the TCR design. Internal testing ensured that the Temperature Controlled Reactor is fully compatible with all accessories provided by Analytical.

Simulated heat maps of a standard 96-well Photoredox Reactor Block vs. a 48-Well Temperature Controlled Reactor (TCR), when used with a Lumidox®II LED array at full power (stage 5).
- Provides users with options to screen either 24 individual 1-DRAM vials (13mm, 15 x 45mm, 4mL) or 48 individual microvials (8 x 30mm) at near-equal temperatures
- Provides extremely uniform thermal control for high throughput experimentation (HTE) with a temperature difference of +/- 1°C. To achieve the performance specifications of the TCR system, the use of a Lumidox®II TCR 48 LED, or 24-18 LED array is required.
- Designed to be used at temperatures between -40°C and 82°C.
- Capable of enhanced re-producibility in heating and cooling applications
- High quality, leak-proof CPC fittings for quick and easy tubing connection
- Compatible with a wide range of heat-transfer fluids such as: water (down to 5°C), silicone-based fluids (ie SYLTHERMTM™), ethylene glycol, and polypropylene glycol
- Designed to standard SLAS dimensions (127.75mm x 85.5mm) with standard 9mm (48-well) or 18mm (24-well) well-to-well pitch
- Compatible with auto-samplers and other staples of high throughput chemistry
- 4mm holes in lid allow for use with most common auto sampler needles
- Threaded holes (6-32) in lid for accessory attachment
- 3.2mm diameter port accommodates standard 3mm thermocouple or cryostat probes for remote temperature measurement
- Each TCR unit undergoes a gas-tight and watertight evaluation before they are released

1 Dram 24-Position TCR
Screen 24 individual 1-DRAM vials (13mm, 15 x 45mm, 4mL) at near-equal temperatures Provides extremely uniform thermal control for high throughput experimentation (HTE) with...Standard (8x30mm) 48-Position TCR
Screen 48 individual microvials (8 x 30mm) at near-equal temperaturesProvides extremely uniform thermal control for high throughput experimentation (HTE) with...
For more information call: 973-616-0700, or fill in the form below and our team will get back to you as soon as possible.