Flow Splitters for Chromatography

Model 62 Stainless Steel Adjustable Flow Splitter
For Pre and Post Column Applications
Splitters
• Bracket Mounted
• Adjustable Metering
• Precise Direct Control
• Fluid Resistor Technology
• Split ratios from 1:1 to 20,000:1
• Low Dead Volume
• Rugged Steel Design
• 5,000 PSI Valve Limit
Adjustable Flow Splitters make it easy to create split ratios from 1:1 up to as high as 20,000:1. Because the Adjustable Flow Splitter incorporates a metering valve, split ratios can be changed frequently with flow changes that are stable and reproducible as noted in figure 1.0. Our Model 62 splitter valve ratios are not affected by changes in solvent viscosities or pressure, which makes this product acceptable for gradient and isocratic applications. Other applications include SCF/MS, where large viscosity changes may be encountered during gradient runs. Applications include isocratic and gradient methods where a reproducible change in the split ratio is acceptable.

Split ratios are created by two fluid resistors that form a parallel flow path. The low flow rate stream passes through a fixed resistor cartridge, while the high flow rate stream passes through an adjustable fluid resistor (metering valve). The ratio of these two resistors creates the split flow ratio. The resulting ratios are stable and repeatable. Because of the rugged design, the split ratio repeatability is ± 1% of setting, and unlike alternative splitter valves or tees, will not be affected by actions that effect input flow such as turning the pump off and on, or pressure spikes.

Pre-Column splitting is used for micro, capillary and nano HPLC applications. Keep in mind that even though the split ratio created by the splitter valve will remain constant; when an HPLC column is installed there will be added resistance on the flow rate channel from the HPLC column. This added resistance must be factored in to make sure the fluid resistor selected for the flow splitter provides the correct split ratio. When ordering a pre-column flow splitter please provide Analytical Sales with the column flow rate and back pressure. If the inlet flow rate or column pressure specifications are not provided, Analytical Sales will configure pre-column flow splitters assuming a 0.5mL/min inlet flow rate and a pressure drop across the column of 1500 PSI.

 

Model 62 Post Column Adjustable Flow Splitters 
Analytical Range: 0.1 - 5mL/min Incoming Flow
Catalog No.
Description
62-414
Adjustable Splitter, Stnls Steel w/ -06 Resistor Cartridge Ratio 1:1 - 20:1
62-413   
Adjustable Splitter, Stnls Steel w/ -04 Resistor Cartridge Ratio 4:1 - 100:1
62-412
Adjustable Splitter, Stnls Steel w/ -03 Resistor Cartridge Ratio 15:1 - 250:1
62-411
Adjustable Splitter, Stnls Steel w/ -01 Resistor Cartridge Ratio 50:1 - 1000:1
   
Replacement Resistor Cartridges for Model 62 Adjustable Flow Splitters
61-115
Analytical -06 Resistor Cartridge     Ratio 1:1 - 20:1
61-114
Analytical -04 Resistor Cartridge     Ratio 4:1 - 100:1
61-113
Analytical -03 Resistor Cartridge     Ratio 15:1 - 250:1
61-112
Analytical -01 Resistor Cartridge     Ratio 50:1 - 1000:1


Adjustable Semi-Prep Flow Splitters
Analytical Range: 5.0 - 40mL/min Incoming Flow

Catalog No.   Description

62-315         Adjustable Semi-Prep Splitter, Stnls Steel 1:1 - 20:1
62-313         Adjustable Semi-Prep Splitter, Stnls Steel 15:1 - 300:1
62-312         Adjustable Semi-Prep Splitter, Stnls Steel 100:1 - 2000:1
62-315         Adjustable Semi-Prep Splitter, Stnls Steel 1000:1 - 20,000:1
 


Replacement Inlet Filters for Adjustable Flow Splitters
Replacing the inlet filter prevents the splitter from clogging

66-063         Replacement Analytical Inlet Filter, 2µm x 0.063 dia., 5/pkg

 


Adjustable Pre-Column Flow Splitters
Pre-Column splitting is used for micro, capillary and nano HPLC applications. The split ratio created by the splitter valve will remain constant, however, when an HPLC column is installed there will be added resistance on the flow rate channel. This added resistance must be considered to ensure the fluid resistor selected for the flow splitter provides the correct split ratio.

When ordering a pre-column flow splitter, please provide the column flow rate and back pressure specifications. If these specifications are not provided, the pre-column flow splitter will be configured assuming a 0.5mL/min inlet flow rate and a pressure drop across the column of 1500psi.

Adjustable Pre-Column Splitter
Analytical Range: 0.1 - 1mL/min Incoming Flow
These splitters will produce under 3500 PSI back pressure with water at 0.5mL/min
Catalog No.   Description

60-101         Adjustable Pre-Column Splitter    Split Ratio Range 50:1 - 1000:1
60-103         Adjustable Pre-Column Splitter    Split Ratio Range 15:1 - 250:1
60-104         Adjustable Pre-Column Splitter    Split Ratio Range 5:1 - 100:1
60-106         Adjustable Pre-Column Splitter    Split Ratio Range 1:1 - 20:1


Replacement Resistor Cartridges for Adjustable Pre-Column Splitters
60-001         Adjustable Pre-column Resistor Cartridge     Split Ratio Range 50:1 - 1000:1
60-003         Adjustable Pre-column Resistor Cartridge     Split Ratio Range 15:1 - 250:1
60-004         Adjustable Pre-column Resistor Cartridge     Split Ratio Range 5:1 - 100:1
60-006         Adjustable Pre-column Resistor Cartridge     Split Ratio Range 1:1 - 20
:1

Model 63 and 53 Fixed Binary and Multiport Flow Splitters

• Fixed metering for precise control
• Fluid Resistor Technology
• Split ratios from 1:1 to 2,000:1
• Low dead volume
• Rugged stainless steel design

 

 

 

The Advantage Fixed Flow Splitters are shipped with resistors installed that deliver the nominal stated split ratio. The split ratios have a tolerance range of ±10%. The exact split ratio is measured and is stated on the certificate shipped with the splitter. The input flow rate can be adjusted to compensate for the tolerance in split ratios. For instance, a 10% increase in input flow rate will result in a 10% increase in flow at both the capillary and waste stream channels. Flow rate and viscosity changes will change the backpressure generated by the splitter, but will not affect the actual split ratio.

These fixed  Flow Splitters can be used for LC/MS, Flow Fractionation, Column Flow Splitting and Capillary Chromatography.

 

Model 63 Post Column Binary Fixed Flow Splitters
Analytical Range: 0.1-5mL/min Incoming Flow

Catalog No.    Description

63-423         Binary Fixed Splitter, Ratio 1:1  
63-422         Binary Fixed Splitter, Ratio 3:1
63-424         Binary Fixed Splitter, Ratio 4:1
63-421         Binary Fixed Splitter, Ratio 5:1
63-420         Binary Fixed Splitter, Ratio 10:1
63-419         Binary Fixed Splitter, Ratio 20:1
63-418         Binary Fixed Splitter, Ratio 50:1
63-417         Binary Fixed Splitter, Ratio 100:1
63-416         Binary Fixed Splitter, Ratio 200:1
63-415         Binary Fixed Splitter, Ratio 500:1
63-414         Binary Fixed Splitter, Ratio 1,000:1
63-413         Binary Fixed Splitter, Ratio 2,000:1
63-666         Binary Fixed Splitter, Custom Ratio
 

Accessories and Replacement Components

63-111         Mounting Bracket for Fixed Splitter

Replacement Inlet Filter, Binary Fixed Splitters, Model 63
Replacing the inlet filter prevents clogging of the splitter
77-125         Binary Analytical Inlet Filter, 2µm x 0.063 dia., 5/pkg

Replacement Resistors for Post Column Binary Fixed Splitters, Model 63
63-443         Replacement Binary Resistor, Ratio 1:1
63-442         Replacement Binary Resistor, Ratio 3:1
63-441         Replacement Binary Resistor, Ratio 5:1
63-440         Replacement Binary Resistor, Ratio 10:1
63-439         Replacement Binary Resistor, Ratio 20:1
63-438         Replacement Binary Resistor, Ratio 50:1
63-437         Replacement Binary Resistor, Ratio 100:1
63-436         Replacement Binary Resistor, Ratio 200:1


Model 63 SEMI-PREP Column Binary Fixed Flow Splitters
Analytical Range: 5.0-40mL/min Incoming Flow

63-405         Binary Fixed Splitter, Ratio 500:1
63-410         Binary Fixed Splitter, Ratio 1,000:1
63-402         Binary Fixed Splitter, Ratio 2,000:1

Replacement Resistors for SEMI-PREP Column
Binary Fixed Splitters, Model 63

63-435         Replacement Binary Resistor, Ratio 500:1
63-434         Replacement Binary Resistor, Ratio 1,000:1
63-433         Replacement Binary Resistor, Ratio 2,000:1
 


 

Model 53 MultiPort Fixed Flow Splitter Manifold
Analytical Range: 0.1 - 5mL/min Incoming Flow 

Multiport Splitters come mounted on a Mounting Bracket   
53-112         3 Port Fixed Splitter, Post-Column, Custom Ratio  
53-114         4 Port Fixed Splitter, Post-Column, Custom Ratio